Please note that editing on this site is now closed. We have moved to a new site right across the road at OpenSmartHouse. The new site offers a better user experience and existing users already registered here with permission to edit the database have been migrated and should be able to log on using the request password link.
Goto this device in the new site
  • Endpoint 0 has no command class linked to the basic class.
  • Endpoint 1 has no command class linked to the basic class.
  • Endpoint 2 has no command class linked to the basic class.

Device Overview

ManufacturerFibargroup
Manufacturer ID010F
NameFGR223
Device DescriptionRoller Shutter 3
CategoryBlinds
References (Type:Id)0303:1000,0303:3000
Firmware VersionsAll
Protocol Version6.002
Library TypeLIB_SLAVE_ENHANCED
Always ListeningYes
Frequently ListeningNo
Supports RoutingYes
Supports BeamingYes
Supports SecurityNo
Maximum Data Rate40000
Device Overview

FIBARO Roller Shutter 3 is a device designed to control roller blinds, awnings, venetian blinds, gates and other single phase, AC powered devices.

Roller Shutter 3 allows precise positioning of roller blinds or venetian blind lamellas. The device is equipped with power and energy monitoring. It allows to control connected devices either via the Z-Wave network or via a switch connected directly to it.

Inclusion Information

Adding (Inclusion) – Z-Wave device learning mode, allowing to add the device to existing Z-Wave network.

To add the device to the Z-Wave network using Smart Start:

  1. Set the main controller in Security S2 Authenticated add mode (see the controller’s manual).
  2. Scan the DSK QR code or input the underlined part of the DSK (label on the bottom of the box).
    (on the device label).
  3. Power the device (turn on the mains voltage).
  4. LED will start blinking yellow, wait for the adding process to end.
  5. Successful adding will be confirmed by the Z-Wave controller’s message.

To add the device to the Z-Wave network manually:

  1. Power the device.
  2. Identify the S1 switch.
  3. Set the main controller in (Security/non-Security Mode) add mode (see the controller’s manual).
  4. Quickly, triple click the S1 switch.
  5. If you are adding in Security S2, scan the DSK QR code or input the underlined part of the DSK (label on the bottom of the box)
  6. Wait for the adding process to end.
  7. Successful adding will be confirmed by the Z-Wave controller’s message.

In case of problems with adding using the S1 switch, use B-button instead (located on the housing).
SmartStart enabled products can be added to SmartStart enabled Z-Wave controller by scanning the Z-Wave QR Code present on the product. SmartStart product will be added automatically within 10 minutes of being switched on in the network range.

Exclusion Information

Removing (Exclusion) – Z-Wave device learning mode, allowing to remove the device from existing Z-Wave network. Removing the device restores all the default parameters of the device, but does not reset power metering data.

To remove the device from the Z-Wave network:

  1. Make sure the device is powered.
  2. Identify the S1 switch.
  3. Set the main controller in remove mode (see the controller’s manual).
  4. Quickly, triple click the S1 switch.
  5. Wait for the removing process to end.
  6. Successful removing will be confirmed by the Z-Wave controller’s message.

In case of problems with removing using the S1 switch, use B-button instead (located on the housing).

If parameter 40 enables scenes for triple S1 click, disable it or use B-button instead to remove the device.

If parameter 24 is set to 1, use S2 switch instead to remove the device.

Usage Information
Basic ClassBASIC_TYPE_ROUTING_SLAVE
Generic ClassGENERIC_TYPE_SWITCH_MULTILEVEL
Specific ClassSPECIFIC_TYPE_CLASS_B_MOTOR_CONTROL
Unique Referencefgr223

Configuration Parameters

Parameter 20
Bitmask
LabelSwitch type
DescriptionSwitch type
Word Size1
Default Value2
Allowable Range0 to 2
Overview

This parameter defines as what type the device should treat the switch connected to the S1 and S2 terminals.

This parameter is not relevant in gate operating modes (parameter 151 set to 3 or 4). In this case switch always works as a momentary and has to be connected to S1 terminal.

If parameter 20 is set to 1 (toggle switch), change value of pa- rameter 153 to 0 for slats to work properly.

Options
Option Value0
Option Labelmomentary switches
Option Overview
Option Value1
Option Labeltoggle switches
Option Overview
Option Value2
Option Labelsingle
Option Overview

momentary switch (the switch should be connected to S1 terminal)

Parameter 24
Bitmask
LabelInputs orientation
DescriptionInputs orientation
Word Size1
Default Value0
Allowable Range0 to 1
Overview

This parameter allows reversing the operation of switches connected to S1 and S2 without changing the wiring.

Options
Option Value0
Option Labeldefault
Option Overview

(S1 - 1st channel, S2 - 2nd channel)

Option Value1
Option Labelreversed
Option Overview

(S1 - 2nd channel, S2 - 1st channel)

Parameter 25
Bitmask
LabelOutputs orientation
DescriptionOutputs orientation
Word Size1
Default Value0
Allowable Range0 to 1
Overview

This parameter allows reversing the operation of Q1 and Q2 without changing the wiring (in case of invalid motor connection) to ensure proper operation.

Options
Option Value0
Option Labeldefault
Option Overview

(Q1 - 1st channel, Q2 - 2nd channel)

Option Value1
Option Labelreversed
Option Overview

(Q1 - 2nd channel, Q2 - 1st channel)

Parameter 30
Bitmask000000FF
LabelAction for Blinds
DescriptionAction for Blinds
Word Size4
Default Value0
Allowable Range0 to 2
Overview
Options
Option Value0
Option LabelNo action
Option Overview
Option Value1
Option LabelOpen blinds
Option Overview
Option Value2
Option LabelClose blinds
Option Overview
Parameter 30
Bitmask0000FF00
LabelEvent/State Parameters - Blinda
DescriptionEvent/State Parameters for blinds
Word Size4
Default Value0
Allowable Range0 to 255
Overview
Options
Parameter 30
Bitmask00FF0000
LabelNotification Status for Blinds
DescriptionNotification Status for Blinds
Word Size4
Default Value0
Allowable Range0 to 255
Overview
Options
Parameter 30
Bitmask7F000000
LabelNotification Type for Blinds
DescriptionNotification Type for Blinds
Word Size4
Default Value0
Allowable Range0 to 255
Overview
Options
Parameter 31
Bitmask000000FF
LabelAction for Water
DescriptionAction for Water
Word Size4
Default Value0
Allowable Range0 to 2
Overview
Options
Option Value0
Option LabelNo action
Option Overview
Option Value1
Option LabelOpen blinds
Option Overview
Option Value2
Option LabelClose blinds
Option Overview
Parameter 31
Bitmask0000FF00
LabelEvent/State Parameters for Water
DescriptionEvent/State Parameters for Water
Word Size4
Default Value0
Allowable Range0 to 255
Overview
Options
Parameter 31
Bitmask00FF0000
LabelNotification Status for Water
DescriptionNotification Status for Water
Word Size4
Default Value255
Allowable Range0 to 255
Overview
Options
Parameter 31
Bitmask7F000000
LabelNotification Type for Water
DescriptionNotification Type for Water
Word Size4
Default Value5
Allowable Range0 to 255
Overview
Options
Parameter 32
Bitmask000000FF
LabelAction for Smoke
DescriptionAction for Smoke
Word Size4
Default Value0
Allowable Range0 to 2
Overview
Options
Option Value0
Option LabelNo action
Option Overview
Option Value1
Option LabelOpen blinds
Option Overview
Option Value2
Option LabelClose blinds
Option Overview
Parameter 32
Bitmask0000FF00
LabelEvent/State Parameters for Smoke
DescriptionEvent/State Parameters for Smoke
Word Size4
Default Value0
Allowable Range0 to 255
Overview
Options
Parameter 32
Bitmask00FF0000
LabelNotification Status for Smoke
DescriptionNotification Status for Smoke
Word Size4
Default Value255
Allowable Range0 to 255
Overview
Options
Parameter 32
Bitmask7F000000
LabelNotification Type for Smoke
DescriptionNotification Type for Smoke
Word Size4
Default Value1
Allowable Range0 to 255
Overview
Options
Parameter 33
Bitmask000000FF
LabelAction for CO
DescriptionAction for CO
Word Size4
Default Value0
Allowable Range0 to 2
Overview
Options
Option Value0
Option LabelNo action
Option Overview
Option Value1
Option LabelOpen blinds
Option Overview
Option Value2
Option LabelClose blinds
Option Overview
Parameter 33
Bitmask0000FF00
LabelEvent/State Parameters for CO
DescriptionEvent/State Parameters for CO
Word Size4
Default Value0
Allowable Range0 to 255
Overview
Options
Parameter 33
Bitmask00FF0000
LabelNotification Status for CO
DescriptionNotification Status for CO
Word Size4
Default Value255
Allowable Range0 to 255
Overview
Options
Parameter 33
Bitmask7F000000
LabelNotification Type for CO
DescriptionNotification Type for CO
Word Size4
Default Value2
Allowable Range0 to 255
Overview
Options
Parameter 34
Bitmask000000FF
LabelAction for Heat
DescriptionAction for Heat
Word Size4
Default Value0
Allowable Range0 to 2
Overview
Options
Option Value0
Option LabelNo action
Option Overview
Option Value1
Option LabelOpen blinds
Option Overview
Option Value2
Option LabelClose blinds
Option Overview
Parameter 34
Bitmask0000FF00
LabelEvent/State Parameters for Heat
DescriptionEvent/State Parameters for Heat
Word Size4
Default Value0
Allowable Range0 to 255
Overview
Options
Parameter 34
Bitmask00FF0000
LabelNotification Status for Heat
DescriptionNotification Status for Heat
Word Size4
Default Value255
Allowable Range0 to 255
Overview
Options
Parameter 34
Bitmask7F000000
LabelNotification Status for Heat
DescriptionNotification Status for Heat
Word Size4
Default Value4
Allowable Range0 to 255
Overview
Options
Parameter 40
Bitmask
LabelS1 Switch Scenes sent
DescriptionParameter values may be combined
Word Size1
Default Value0
Allowable Range0 to 15
Overview
Options
Parameter 41
Bitmask
LabelS2 Switch Scenes sent
DescriptionParameter values may be combined
Word Size1
Default Value0
Allowable Range0 to 15
Overview
Options
Parameter 60
Bitmask
LabelMeasuring power consumed by the device itself
DescriptionMeasuring power consumed by the device itself
Word Size1
Default Value0
Allowable Range0 to 1
Overview
Options
Option Value0
Option LabelFunction inactive
Option Overview
Option Value1
Option LabelFunction active
Option Overview
Parameter 61
Bitmask
LabelPower reports - on change
DescriptionPower reports - on change
Word Size2
Default Value15
Allowable Range0 to 500
Overview
Options
Parameter 62
Bitmask
LabelPower reports - periodic
DescriptionPower reports - periodic
Word Size2
Default Value3600
Allowable Range0 to 32400
Overview
Options
Parameter 65
Bitmask
LabelEnergy reports - on change
DescriptionEnergy reports - on change
Word Size2
Default Value10
Allowable Range0 to 500
Overview
Options
Parameter 66
Bitmask
LabelEnergy reports - periodic
DescriptionEnergy reports - periodic
Word Size2
Default Value3600
Allowable Range0 to 32400
Overview
Options
Parameter 150
Bitmask
LabelForce calibration
DescriptionForce calibration
Word Size1
Default Value0
Allowable Range0 to 2
Overview

By setting this parameter to 2 the device enters the calibration mode. The parameter relevant only if the device is set to work in positioning mode (parameter 151 set to 1, 2 or 4).

Options
Option Value0
Option Labeldevice is not calibrated
Option Overview
Option Value1
Option Labeldevice is calibrated
Option Overview
Option Value2
Option Labelforce device calibration
Option Overview
Parameter 151
Bitmask
LabelOperating mode
DescriptionOperating mode
Word Size1
Default Value1
Allowable Range1 to 6
Overview

This parameter allows adjusting operation according to the connect- ed device.

Options
Option Value1
Option Labelroller blind
Option Overview

with positioning

Option Value2
Option LabelVenetian blind
Option Overview

with positioning

Option Value3
Option Labelgate w/o positioning
Option Overview
Option Value4
Option Labelgate with positioning
Option Overview
Option Value5
Option Labelroller blind with built-in driver
Option Overview
Option Value6
Option Labelroller blind with built-in driver (impulse)
Option Overview
Parameter 152
Bitmask
LabelVenetian blind - time of full turn of the slats
DescriptionVenetian blind - time of full turn of the slats
Word Size4
Default Value150
Allowable Range0 to 90000
Overview
Options
Parameter 153
Bitmask
LabelSet slats back to previous position
DescriptionSet slats back to previous position
Word Size1
Default Value1
Allowable Range0 to 2
Overview

For Venetian blinds (parameter 151 set to 2) the parameter determines slats positioning in various situations.
The parameter is irrelevant for other modes.
If parameter 20 is set to 1 (toggle switch), change value of pa- rameter 153 to 0 for slats to work properly.

Options
Option Value0
Option Labelslats return #1
Option Overview

Slats return to previously set position only in case of the main controller operation.

Option Value1
Option Labelslats return #2
Option Overview

Slats return to previously set position in case of the main controller operation, momentary switch operation, or when the limit switch is reached.

Option Value2
Option Labelslats return #3
Option Overview

Slats return to previously set position in case of the main controller operation, momen- tary switch operation, when the limit switch is reached or after receiving the Switch Multilevel Stop control frame

Parameter 154
Bitmask
LabelDelay motor stop
DescriptionDelay motor stop after reaching end switch
Word Size2
Default Value10
Allowable Range0 to 600
Overview
Options
Parameter 155
Bitmask
LabelMotor operation detection
DescriptionMotor operation detection
Word Size2
Default Value10
Allowable Range0 to 255
Overview
Options
Parameter 156
Bitmask
LabelTime of up movement
DescriptionTime of up movement
Word Size4
Default Value6000
Allowable Range0 to 90000
Overview
Options
Parameter 157
Bitmask
LabelTime of down movement
DescriptionTime of down movement
Word Size4
Default Value6000
Allowable Range0 to 90000
Overview
Options

Association Groups

Group ID1
LabelLifeline
Description
Maximum Nodes1
ControllerYes
Overview
Group ID2
LabelRoller Shutter
DescriptionShutter position control
Maximum Nodes5
ControllerNo
Overview

"Roller Shutter" is assigned to shutter position control – UP/DOWN (uses Switch Multilevel command class).

Group ID3
LabelSlats
DescriptionSlats position control
Maximum Nodes5
ControllerNo
Overview

"Slats" is assigned to slats position control – UP/DOWN (uses Switch Multilevel command class).

Endpoints

Endpoint NameEndpoint 0
Endpoint Number0
Basic ClassBASIC_TYPE_ROUTING_SLAVE
Generic ClassGENERIC_TYPE_SWITCH_MULTILEVEL
Specific ClassSPECIFIC_TYPE_CLASS_B_MOTOR_CONTROL
Command Classes
Class Ver Basic NIF Sec UnSec
NO_OPERATION 1
BASIC 1
APPLICATION_STATUS 1
SWITCH_MULTILEVEL 3
Blinds Control [deprecated]
METER 3
Electric meter (kWh)
Electric meter (watts)
CRC_16_ENCAP 1
ASSOCIATION_GROUP_INFO 1
DEVICE_RESET_LOCALLY 1
CENTRAL_SCENE 3
Scene Number
ZWAVE_PLUS_INFO 1
MULTI_INSTANCE 2
CONFIGURATION 1
ALARM 8
Alarm (power)
Alarm (system)
MANUFACTURER_SPECIFIC 1
POWERLEVEL 1
PROTECTION 2
FIRMWARE_UPDATE_MD 1
ASSOCIATION 2
VERSION 2
MULTI_INSTANCE_ASSOCIATION 3
SECURITY 1
Endpoint NameEndpoint 1
Endpoint Number1
Basic ClassBASIC_TYPE_ROUTING_SLAVE
Generic ClassGENERIC_TYPE_SWITCH_MULTILEVEL
Specific ClassSPECIFIC_TYPE_CLASS_B_MOTOR_CONTROL
Command Classes
Class Ver Basic NIF Sec UnSec
BASIC
APPLICATION_STATUS 1
SWITCH_MULTILEVEL 3
Blinds Control
METER 3
Electric meter (kWh) 1
Electric meter (watts) 1
ASSOCIATION_GROUP_INFO 1
ZWAVE_PLUS_INFO 1
ALARM 8
Alarm (power) 1
Alarm (system) 1
ASSOCIATION 2
MULTI_INSTANCE_ASSOCIATION 3
SECURITY 1
Endpoint NameEndpoint 2
Endpoint Number2
Basic ClassBASIC_TYPE_ROUTING_SLAVE
Generic ClassGENERIC_TYPE_SWITCH_MULTILEVEL
Specific ClassSPECIFIC_TYPE_CLASS_B_MOTOR_CONTROL
Command Classes
Class Ver Basic NIF Sec UnSec
BASIC
APPLICATION_STATUS 1
SWITCH_MULTILEVEL 3
Lamella Control
ASSOCIATION_GROUP_INFO 1
ZWAVE_PLUS_INFO 1
ASSOCIATION 2
MULTI_INSTANCE_ASSOCIATION 3
SECURITY 1

Reference Documents

Operating Manuel (English) FGR-223-EN-T-v1-0.pdf
Product Image roller-device-1.jpg

First added to database on -0001-11-30 00:00:00. Current released version is 10.
Last updated by Günter Lepenat on 2020-07-27 08:24:43 (3 months ago).
Approved on 2020-08-02 07:59:55, and last exported on 2020-08-02 07:59:59.

Comments  
# sihui 2019-01-28 12:11
Changed switch_dimmer channels to blinds_control for all endpoints according to this PR:
https://github.com/openhab/org.openhab.binding.zwave/pull/1120

You have no rights to post comments