• Endpoint 0 has no command class linked to the basic class.

Device Overview

ManufacturerBuilding 36 Technologies
Manufacturer ID0190
NameADC-T 2000
Device DescriptionAlarm.com Smart Thermostat
CategoryHVAC
References (Type:Id)0001:0001
Firmware VersionsAll
Protocol Version3.095
Library TypeLIB_SLAVE_ENHANCED
Always ListeningNo
Frequently ListeningNo
Supports RoutingNo
Supports BeamingNo
Supports SecurityNo
Maximum Data Rate
Device Overview
  • Intelligently Connected with Alarm.com (Alarm.com account required)
  • Remote Access and Control
  • Custom Schedules
  • Critical Temperature Alerts and Geo-Services Automation
  • Can be paired with Alarm.com Temperature Sensor ADC-S2000-T-RA for enhanced climate control and improved energy savings (sold separately)
Inclusion Information

Put thermostat in OFF mode (no mode icons are lit)

Press and hold the DOWN button to begin inclusion mode. Release when the RADIO icon lights up.

When the RADIO icon becomes solid, the thermostat has been included.

Exclusion Information

Put thermostat in OFF mode (no mode icons are lit)

Press and hold the DOWN button to begin exclusion mode. Release when the RADIO icon lights up.

When the RADIO icon flashes red, the thermostat has been excluded.

Usage Information
Basic ClassBASIC_TYPE_ROUTING_SLAVE
Generic ClassGENERIC_TYPE_THERMOSTAT
Specific ClassSPECIFIC_TYPE_THERMOSTAT_GENERAL_V2
Unique Referenceadct2000

Configuration Parameters

Parameter 1
Bitmask
LabelHVAC System Type
DescriptionConfigures the type of heating system used.
Word Size1
Default Value0
Allowable Range0 to 1
Overview

0 - Normal (Default)

1 - Heat Pump

Options
Option Value0
Option LabelNormal
Option Overview
Option Value1
Option LabelHeat Pump
Option Overview
Parameter 2 [ADVANCED]
Bitmask
LabelNumber of Heat Stages
DescriptionHeat Stages 0-3 Default is 2.
Word Size1
Default Value2
Allowable Range0 to 3
Overview
Options
Parameter 3 [ADVANCED]
Bitmask
LabelNumber of Cool Stages
DescriptionCool Stages 0-2 Default is 2.
Word Size1
Default Value2
Allowable Range0 to 2
Overview
Options
Parameter 4
Bitmask
LabelHeat Fuel Type
DescriptionChoose type of fuel. Reality - whether unit is boiler vs forced air.
Word Size1
Default Value1
Allowable Range0 to 1
Overview

0 - Fossil Fuel

1 - Electric (Default)

Options
Option Value0
Option LabelFossil Fuel
Option Overview

Fossil 2-Heat 2-Cool System (for hydronic heat w/ no fan)

Option Value1
Option LabelElectric
Option Overview

Normal 2-Heat 2-Cool System

Parameter 5
Bitmask
LabelCalibration Temperature
DescriptionCalibration Temperature Range (in deg. F) Precision is tenths of a degree.
Word Size4
Default Value0
Allowable Range-100 to 100
Overview
Options
Parameter 6 [ADVANCED]
Bitmask
LabelOvershoot
DescriptionOvershoot Range (in deg. F) Precision is tenths of a degree. Default is 5.
Word Size4
Default Value5
Allowable Range0 to 30
Overview
Options
Parameter 7 [ADVANCED]
Bitmask
LabelSwing
DescriptionSwing Range (in deg. F) Precision is tenths of a degree.
Word Size4
Default Value0
Allowable Range0 to 30
Overview
Options
Parameter 8 [ADVANCED]
Bitmask
LabelHeat Staging Delay
DescriptionHeat Staging Delay (in min)
Word Size1
Default Value10
Allowable Range1 to 60
Overview
Options
Parameter 9 [ADVANCED]
Bitmask
LabelCool Staging Delay
DescriptionCool Staging Delay (in min)
Word Size1
Default Value10
Allowable Range1 to 60
Overview
Options
Parameter 10 [ADVANCED]
Bitmask
LabelBalance Setpoint
DescriptionBalance Setpont Range (in deg. F) Precision is tenths of a degree.
Word Size4
Default Value350
Allowable Range0 to 950
Overview
Options
Parameter 11
Bitmask
LabelRecovery Settings
DescriptionWhether thermostat uses intelligence to try and make the best of energy usage.
Word Size1
Default Value1
Allowable Range0 to 1
Overview

0 - Comfort

1 - Efficient (Default)

Options
Option Value0
Option LabelComfort
Option Overview
Option Value1
Option LabelEfficient
Option Overview
Parameter 12 [ADVANCED]
Bitmask
LabelFan Circulation Period
DescriptionFan Circulation Period (in min)
Word Size1
Default Value20
Allowable Range10 to 240
Overview
Options
Parameter 13 [ADVANCED]
Bitmask
LabelFan Circulation Duty Cycle
DescriptionDuty Cycle (percentage)
Word Size1
Default Value25
Allowable Range0 to 100
Overview
Options
Parameter 14 [ADVANCED]
Bitmask
LabelFan Purge Time
DescriptionPurge Time (in s)
Word Size2
Default Value60
Allowable Range1 to 3600
Overview
Options
Parameter 15
Bitmask
LabelMaximum Heat Setpoint
DescriptionMax Heat Setpoint Range (in deg. F) Precision is tenths of a degree.
Word Size4
Default Value950
Allowable Range350 to 950
Overview
Options
Parameter 16
Bitmask
LabelMinimum Heat Setpoint
DescriptionMin Heat Setpoint Range (in deg. F) Precision is tenths of a degree.
Word Size4
Default Value350
Allowable Range350 to 950
Overview
Options
Parameter 17
Bitmask
LabelMaximum Cool Setpoint
DescriptionMax Cool Setpoint Range(in deg. F) Precision is tenths of a degree.
Word Size4
Default Value950
Allowable Range500 to 950
Overview
Options
Parameter 18
Bitmask
LabelMinimum Cool Setpoint
DescriptionMin Cool Setpoint (in deg. F) Precision is tenths of a degree.
Word Size4
Default Value500
Allowable Range500 to 950
Overview
Options
Parameter 19
Bitmask
LabelThermostat Lock
DescriptionLock out physical thermostat controls.
Word Size1
Default Value0
Allowable Range0 to 1
Overview

0 - Disabled (Default)

1 - Enabled

Options
Option Value0
Option LabelDisabled
Option Overview
Option Value1
Option LabelEnabled
Option Overview
Parameter 20 [ADVANCED]
Bitmask
LabelCompressor Delay
DescriptionCompressor Delay (in min)
Word Size1
Default Value5
Allowable Range0 to 60
Overview
Options
Parameter 21 [ADVANCED]
Bitmask
LabelDemand Response Period
DescriptionDemand Response Period (in min)
Word Size1
Default Value10
Allowable Range10 to 240
Overview
Options
Parameter 22 [ADVANCED]
Bitmask
LabelDemand Response Duty Cycle
DescriptionDemand Response Duty Cycle (percentage)
Word Size1
Default Value25
Allowable Range0 to 100
Overview
Options
Parameter 23
Bitmask
LabelTemperature Display Units
DescriptionCelsius or Farenheit for temperature display.
Word Size1
Default Value1
Allowable Range0 to 1
Overview

0 - Celsius

1 - Farenheit (Default)

Options
Option Value0
Option LabelCelsius
Option Overview
Option Value1
Option LabelFarenheit
Option Overview
Parameter 24
Bitmask
LabelHVAC Modes Enabled
DescriptionWhich heating/cooling modes are available.
Word Size1
Default Value15
Allowable Range3 to 31
Overview

3 - Off, Heat
5 - Off, Cool
7 - Off, Heat, Cool
15 - Off, Heat, Cool, Auto (Default)
19 - Off, Heat, Emergency Heat
23 - Off, Heat, Cool, Emergency Heat
31 - Off, Heat, Cool, Auto, Emergency Heat

Options
Option Value3
Option LabelOff, Heat
Option Overview
Option Value5
Option LabelOff, Cool
Option Overview
Option Value7
Option LabelOff, Heat, Cool
Option Overview
Option Value15
Option LabelOff, Heat, Cool, Auto (Default)
Option Overview
Option Value19
Option LabelOff, Heat, Emergency Heat
Option Overview
Option Value23
Option LabelOff, Heat, Cool, Emergency Heat
Option Overview
Option Value31
Option LabelOff, Heat, Cool, Auto, Emergency Heat
Option Overview
Parameter 25
Bitmask
LabelConfigurable Terminal Setting
DescriptionChanges control of configurable terminal
Word Size1
Default Value0
Allowable Range0 to 3
Overview

0 - Disabled (Default)
1 - W3 - Third Stage HEAT or 2nd Stage of 2-Stage Auxiliary / Backup heat
2 - H - External Dehumidifier Control
3 - DH - External Dehumidifier Operation

Options
Option Value0
Option LabelDisabled
Option Overview
Option Value1
Option LabelW3
Option Overview
Option Value2
Option LabelH
Option Overview
Option Value3
Option LabelDH
Option Overview
Parameter 26
Bitmask
LabelPower Source
DescriptionWhich source of power is utilized.
Word Size1
Default Value0
Allowable Range0 to 1
Overview

0 - Battery (Default)

1 - C-Wire

Options
Option Value0
Option LabelBattery
Option Overview
Option Value1
Option LabelC-Wire
Option Overview
Parameter 27 [ADVANCED]
Bitmask
LabelBattery Alert Threshold Low
DescriptionBattery Alert Range (percentage)
Word Size1
Default Value30
Allowable Range0 to 100
Overview
Options
Parameter 28 [ADVANCED]
Bitmask
LabelBattery Alert Threshold Very Low
DescriptionVery Low Battery Alert Range (percentage)
Word Size1
Default Value15
Allowable Range0 to 100
Overview
Options
Parameter 30 [ADVANCED]
Bitmask
LabelRemote Temperature Enable
DescriptionEnables remote temperature sensor instead of built-in.
Word Size1
Default Value0
Allowable Range0 to 1
Overview

0 - Disabled (Default)

1 - Enabled

Options
Option Value0
Option LabelDisabled
Option Overview
Option Value1
Option LabelEnabled
Option Overview
Parameter 31 [ADVANCED]
Bitmask
LabelHeat Differential
DescriptionHeat Differential (in deg. F) Precision is tenths of a degree.
Word Size4
Default Value30
Allowable Range10 to 100
Overview
Options
Parameter 32 [ADVANCED]
Bitmask
LabelCool Differential
DescriptionCool Differential (in deg. F) Precision is tenths of a degree.
Word Size4
Default Value30
Allowable Range10 to 100
Overview
Options
Parameter 33 [ADVANCED]
Bitmask
LabelTemperature Reporting Threshold
DescriptionTemperature Reporting Range (in deg. F) Precision is tenths of a degree.
Word Size4
Default Value10
Allowable Range5 to 20
Overview
Options
Parameter 34 [ADVANCED]
Bitmask
LabelO/B Select
DescriptionConfiguration of O/B terminal.
Word Size1
Default Value1
Allowable Range0 to 1
Overview

0 - O/B Terminal acts as B terminal, closed when cooling
1 - O/B Terminal acts as O terminal, closed when heating (Default)

Options
Option Value0
Option LabelO/B as B
Option Overview
Option Value1
Option LabelO/B as O
Option Overview
Parameter 35 [ADVANCED]
Bitmask
LabelZ-Wave Echo Association Reports
DescriptionEnable/Disabled Echo Assoc. Reports.
Word Size1
Default Value0
Allowable Range0 to 1
Overview

0 - Disabled (Default)

1 - Enabled

Options
Option Value0
Option LabelDisabled
Option Overview
Option Value1
Option LabelEnabled
Option Overview

Association Groups

Group ID1
LabelLifeline
DescriptionZ-Wave Plus Lifeline
Maximum Nodes4
ControllerYes
Overview

Endpoints

Endpoint NameEndpoint 0
Endpoint Number0
Basic ClassBASIC_TYPE_ROUTING_SLAVE
Generic ClassGENERIC_TYPE_THERMOSTAT
Specific ClassSPECIFIC_TYPE_THERMOSTAT_GENERAL_V2
Command Classes
Class Ver Basic NIF Sec UnSec
BASIC 1
SENSOR_MULTILEVEL 6
Sensor (temperature)
Sensor (relative humidity)
THERMOSTAT_MODE 1
Thermostat mode
Auto
Heat
Off
Cool
THERMOSTAT_OPERATING_STATE 1
Operating State
THERMOSTAT_SETPOINT 1
Setpoint (heating)
Setpoint (cooling)
THERMOSTAT_FAN_MODE 1
Thermostat fan mode
On (Low)
Circulate
Auto (Low)
THERMOSTAT_FAN_STATE 1
Thermostat fan state
Idle
ASSOCIATION_GROUP_INFO 1
DEVICE_RESET_LOCALLY 1
ZWAVE_PLUS_INFO 1
CONFIGURATION 1
MANUFACTURER_SPECIFIC 1
POWERLEVEL 1
FIRMWARE_UPDATE_MD 1
BATTERY 1
CLOCK 1
Clock Time Offset
ASSOCIATION 2
VERSION 2

Reference Documents

Product Image 91hemIL-XkL--SL1500-.jpg
Product Manual Smart-Thermostat-Product-Manual1.pdf

First added to database on -0001-11-30 00:00:00. Current released version is 2.
Last updated by Tom Flicker on 2018-11-25 17:10:49 (1 year ago).
Approved on 2018-11-27 21:46:07, and last exported on 2019-12-25 13:37:00.