Device Overview

Danalock supports:

  • S0/S2 Z-Wave Security
  • Bluetooth Smart
  • Twist Assist
  • Auto Lock
  • Hold And Release
  • Back To Back 
Inclusion Information

To add or include the Danalock into a Z-Wave network

  1. Pair the lock with bluetooth first
  2. Set the controller in inclusion mode

  3. Push the switch once.

  4. Wait 5 seconds. 

Exclusion Information

To remove or exclude the Danalock into a Z-Wave network

  1. Delete the lock within the app (bluetooth)
  2. Set the controller in exclusion mode

  3. Push the switch once.

  4. Wait 5 seconds. 

Usage Information

Additional hints:

Inclusion: Do not include the lock to a Z-Wave network before it has been paired through bluetooth. Otherwise the lock is blocked and you are not able to pair through bluetooth. If you are not able to pair through the app then there is still z-wave information that has not been erased. A factory reset does not delete this Z-Wave information. You must exclude.

Exclusion: Delete the lock from the app before you exclude. Otherwise it won’t work. Exclusion is successful when the green light stops lightning immediately. If you use the Aeotec Z-Stick Gen5 it is easier to exclude with the USB stick detached. Inclusion of course with the stick attached to the PC. You can use any kind of controller to exclude - no matter with which controller it has been paired before.

Basic ClassBASIC_TYPE_ROUTING_SLAVE
Generic ClassGENERIC_TYPE_ENTRY_CONTROL
Specific ClassSPECIFIC_TYPE_SECURE_KEYPAD_DOOR_LOCK
Unique Referencebtze

Configuration Parameters

Parameter 1
Bitmask
LabelTwin Assist
DescriptionHelps you to lock and unlock your door lock.
Word Size1
Default Value0
Allowable Range0 to 1
Overview

0 -> disabled

1 -> enabled

Options
Option Value0
Option Labeldisabled
Option Overview
Option Value1
Option Labelenabled
Option Overview
Parameter 2
Bitmask
LabelHold and Release
DescriptionAfter a unlock operation the lock holds the lock, so the door can be opened
Word Size4
Default Value0
Allowable Range0 to 2147483647
Overview

0 -> disabled

1 to 2147483647 -> enabled no. of seconds

Options
Option Value0
Option LabelDisabled
Option Overview
Parameter 3
Bitmask
LabelBlock to block
DescriptionThe lock will run the motor until it hits resistance.
Word Size1
Default Value0
Allowable Range0 to 1
Overview
Options
Option Value0
Option LabelDisabled
Option Overview
Option Value1
Option LabelEnabled
Option Overview
Parameter 4
Bitmask
LabelBLE Temporary Allowed
DescriptionThe BLE is enabled for a number of seconds.
Word Size4
Default Value0
Allowable Range0 to 2147483647
Overview

0 -> Disabled

1 to 2147483647 -> enabled no. of seconds

Options
Parameter 5
Bitmask
LabelBLE Always Allowed
DescriptionBLE Always Allowed
Word Size1
Default Value0
Allowable Range0 to 1
Overview

0 -> BLE Always disabled

1 -> BLE Always enabled

Options
Option Value0
Option LabelBLE Always disabled
Option Overview
Option Value1
Option LabelBLE Always enabled
Option Overview
Parameter 6
Bitmask
LabelAutolock
DescriptionLock after an unlock.Value is delay in sec before lock is locked again.
Word Size4
Default Value0
Allowable Range0 to 2147483647
Overview

0 -> disabled

1 to 2147483647 -> enabled no. of seconds

Options

Association Groups

Group ID1
LabelLifeline
DescriptionZ-Wave Plus Lifeline
Maximum Nodes1
ControllerYes
Overview

Z-Wave Plus Lifeline

  • Device Reset Locally: triggered upon reset.
  • Battery/notification: triggered upon low battery.
  • Door Lock operation report: triggered upon a change in door lock
  • Notification: triggered upon a change in door lock

Endpoints

Endpoint NameEndpoint 0
Endpoint Number0
Basic ClassBASIC_TYPE_ROUTING_SLAVE
Generic ClassGENERIC_TYPE_ENTRY_CONTROL
Specific ClassSPECIFIC_TYPE_SECURE_KEYPAD_DOOR_LOCK
Command Classes
Class Ver Basic NIF Sec UnSec
ASSOCIATION_GROUP_INFO 1
DEVICE_RESET_LOCALLY 1
ZWAVE_PLUS_INFO 2
DOOR_LOCK 2
Door Lock
CONFIGURATION 1
MANUFACTURER_SPECIFIC 2
POWERLEVEL 1
FIRMWARE_UPDATE_MD 4
BATTERY 1
ASSOCIATION 2
VERSION 2
SECURITY 1

Reference Documents

Product manual Danalock-V3-Product-manual-Z-Wave-V-0-9-1.pdf
Product Image Danalock-V3-BTZE.jpeg

First added to database on 2018-03-21 20:58:27. Current released version is 6.
Last updated by Kyle on 2019-01-18 03:17:28 (8 months ago).
Approved on 2019-01-18 22:14:32, and last exported on 2019-01-18 22:14:33.

Comments  
# Thilo 2017-10-09 20:44
The following command classes are specified in the manufacturer's manual but could no be selected in the input masks "endpoints":
- Notification
- Security S2
- Supervision
- Transport Service
Reply | Reply with quote | Quote