• Endpoint 0 has no command class linked to the basic class.

Device Overview

ManufacturerStelpro
Manufacturer ID0239
NameSTZW402
Device Description4000W Thermostat
CategoryHVAC
References (Type:Id)0001:0001
Firmware VersionsAll
Protocol Version4.005
Library TypeLIB_CONTROLLER_BRIDGE
Always ListeningYes
Frequently ListeningNo
Supports RoutingYes
Supports BeamingYes
Supports SecurityNo
Maximum Data Rate40000
Device Overview

Ki, the smart home line-voltage thermostat by Stelpro - STZW402+

  • The very first Z-Wave Plus line voltage thermostat in North America
  •  Supports 120Vac - 240Vac (50/60 Hz) voltages
  •  Controls baseboard heaters and convectors up to 4000W
  •  Easy to use 2 button interface
  •  Made in Canada
  •  High precision temperature control +/- 0.1 °C
  •  Z-Wave Plus certified, works with thousands of other Z-Wave devices
  •  Brings optimal comfort into your smart home
  •  Can be integrated into smart home automated scenes
  •  Local keypad lock
  •  Displays external temperature
  •  Adjustable backlight intensity
  •  Comfort and Eco modes
  •  Celsius or Fahrenheit display
  •  Quiet TRIAC operation
  •  Frost-free warning
  •  Sleek design to harmonize with any decor
Inclusion Information
  1. Enter the Menu 1 (Z-Wave menu) and select “On”.
  2. Press the UP and DOWN buttons to start the inclusion process.

During inclusion, “On” will be blinking and the connectivity icon  will be animated in an increasing pattern. When the inclusion process has been completed, On will be displayed solid. If an error occurs, “Err” will be displayed for 3 seconds then the screen will revert to “Off” selection.

Exclusion Information
  1. Enter the Menu1 (Z-Wave menu) and select “Off”.
  2. Press the UP and DOWN buttons to start the exclusion process.

During exclusion, “Off” will be blinking and the connectivity icon  will be animated in an decreasing pattern. When the exclusion process has been completed, Off will be displayed solid. If an error occurs, “Err” will be displayed for 3 seconds then the screen will revert to “On” selection.

Usage Information
Basic ClassBASIC_TYPE_ROUTING_SLAVE
Generic ClassGENERIC_TYPE_THERMOSTAT
Specific ClassSPECIFIC_TYPE_THERMOSTAT_GENERAL_V2
Unique Referencestzw402

Configuration Parameters

None

Association Groups

Group ID1
LabelLifeline
DescriptionReports state to the main controller
Maximum Nodes1
ControllerYes
Overview

Endpoints

Endpoint NameEndpoint 0
Endpoint Number0
Basic ClassBASIC_TYPE_ROUTING_SLAVE
Generic ClassGENERIC_TYPE_THERMOSTAT
Specific ClassSPECIFIC_TYPE_THERMOSTAT_GENERAL_V2
Command Classes
Class Ver Basic NIF Sec UnSec
NO_OPERATION 1
BASIC 1
SENSOR_MULTILEVEL 1
Sensor (temperature)
THERMOSTAT_MODE 2
Thermostat mode
Heat
Economy Heat
THERMOSTAT_OPERATING_STATE 1
Operating State
THERMOSTAT_SETPOINT 2
Setpoint (heating)
ASSOCIATION_GROUP_INFO
DEVICE_RESET_LOCALLY 1
ZWAVE_PLUS_INFO 1
MANUFACTURER_SPECIFIC 1
POWERLEVEL 1
ASSOCIATION 1
VERSION 1

Reference Documents

User Manual INS-STZW402-1215-EN-0.pdf
Image STZW402.png

First added to database on 2016-10-13 07:23:46. Current released version is 1.
Last updated by Super User on 2019-09-15 22:21:07 (11 months ago).
Approved on 2019-09-15 22:21:17, and last exported on 2019-12-25 13:26:12.