• Endpoint 0 has no command class linked to the basic class.

Device Overview

ManufacturerHorstmann Controls Limited
Manufacturer ID0059
NameHRT4-ZW
Device DescriptionBattery Powered Wall Thermostat
CategoryHVAC
References (Type:Id)0001:0003
Firmware VersionsAll
Protocol Version2.078
Library TypeLIB_CONTROLLER
Always ListeningNo
Frequently ListeningNo
Supports RoutingNo
Supports BeamingYes
Supports SecurityNo
Maximum Data Rate40000
Device Overview

Wireless Z–Wave Battery Operated Electronic Room Thermostat with TPI temperature control software and ASR-ZW receiver unit

Inclusion Information
  1. Set the number 1 DIL switch on the back of the HRT4-ZW thermostat to the On (Up) position and the display on the HRT4-ZW will change to show the letter ‘I’. If the letter ‘L’ appears, carry out stage 1A opposite.
  2. Power up the ASR-ZW receiver unit
  3. The network LED on the ASR-ZW receiver should be flashing.
  4. Press the dial on the front of the HRT4-ZW thermostat once so that the ‘I’ in the display flashes.
  5. Press and hold the network button on the ASR-ZW receiver until the On indicator flashes (green) before the Off indicator
    becomes solid red.
  6. After a few seconds the radio mast symbol will appear in the display along with the letters IP.
  7. Reset the number 1 DIL switch on the back of the HRT4-ZW to the Off position and the temperature should return in the display
Exclusion Information

Not provided

Wakeup Information
  1. Turn the dial of the HRT4-ZW until the letter P appears in the display.
  2. Press the dial twice.
  3. A second P should appear in the display which now shows `PP’.
  4. Turn the dial until the letter ‘I’ appears in the display and return to the main instruction.
Usage Information
Basic ClassBASIC_TYPE_CONTROLLER
Generic ClassGENERIC_TYPE_THERMOSTAT
Specific ClassSPECIFIC_TYPE_NOT_USED
Unique Referencehrt4zw

Configuration Parameters

Parameter 1
Bitmask
LabelEnable Temperature Sensor
DescriptionControls the use of the temperature sensor on the device
Word Size1
Default Value0
Allowable Range0 to 255
Overview
Options
Option Value0
Option LabelDisable
Option Overview
Option Value255
Option LabelEnable
Option Overview
Parameter 2
Bitmask
LabelTemperature Scale
DescriptionControls the temperature sensor scale
Word Size1
Default Value0
Allowable Range0 to 255
Overview
Options
Option Value0
Option LabelCelsius
Option Overview
Option Value255
Option LabelFahrenheit
Option Overview
Parameter 3
Bitmask
LabelDelta T
DescriptionDefines the temperature steps of the heating control. Steps are 0.1 K
Word Size1
Default Value10
Allowable Range0 to 255
Overview
Options

Association Groups

Group ID1
LabelThermostat Mode Set
Description
Maximum Nodes4
ControllerYes
Overview
Group ID2
LabelBinary Switch Set
Description
Maximum Nodes4
ControllerYes
Overview
Group ID3
LabelUnsolicited Battery Level Reports
Description
Maximum Nodes4
ControllerYes
Overview
Group ID4
LabelThermostat Set Point Reports
Description
Maximum Nodes4
ControllerYes
Overview
Group ID5
LabelUnsolicited Sensor Multilevel Reports
Description
Maximum Nodes4
ControllerYes
Overview

Endpoints

Endpoint NameEndpoint 0
Endpoint Number0
Basic ClassBASIC_TYPE_CONTROLLER
Generic ClassGENERIC_TYPE_THERMOSTAT
Specific Class
Command Classes
Class Ver Basic NIF Sec UnSec
NO_OPERATION 1
BASIC 1
SWITCH_BINARY
Switch
SENSOR_MULTILEVEL 1
Sensor (temperature)
THERMOSTAT_MODE
Thermostat mode
Heat
Off
THERMOSTAT_SETPOINT 1
Setpoint (heating)
CONFIGURATION 1
MANUFACTURER_SPECIFIC 1
BATTERY 1
WAKE_UP 2
ASSOCIATION 1
VERSION 1

Reference Documents

User Guide user-and-installer-guide-HRT4-ZWweb1.pdf
Product Image HRT4-ZW-White.jpg

First added to database on 2018-01-20 09:01:46. Current released version is 4.
Last updated by sihui on 2019-01-11 11:49:47 (5 months ago).
Approved on 2019-01-11 11:49:51, and last exported on 2019-01-11 11:49:52.

Comments  

# Pedro J. 2017-06-17 05:41
Excuse me, I press the button in error
Reply | Reply with quote | Quote

Add comment


Security code
Refresh