Device Overview

ManufacturerDevolo
Manufacturer ID0175
NameMT02648
Device DescriptionDoor/Window Contact
CategoryDoor
References (Type:Id)0002:000E
Firmware VersionsAll
Protocol Version3.095
Library TypeLIB_SLAVE_ENHANCED
Always ListeningNo
Frequently ListeningNo
Supports RoutingYes
Supports BeamingYes
Supports SecurityNo
Maximum Data Rate40000
Device Overview

The Door/Window Contact and the Motion Detector have two additional functions integrated: temperature and illumination measurement, based on Z-WaveTM technology.

Inclusion Information
  1. Have Z-WaveTM Controller entered inclusion mode.
  2. Pressing tamper key three times within 1.5 seconds to enter the inclusion mode.
  3. After inclusion successful, the device will wake to receive the setting command from Z-WaveTM Controller about 20 seconds.
Exclusion Information
  1. Have Z-WaveTM Controller entered exclusion mode.
  2. Pressing tamper key three times within 1.5 seconds to enter the exclusion mode.
    Node ID has been excluded.


Reset:
Notice: Use this procedure only in the event that the primary controller is lost or otherwise inoperable.

  1. Pressing tamper key four times within 1.5 seconds and do not release the tamper key in the 4th pressed, and the LED will light ON.
  2. After 3 seconds the LED will turn OFF, after that within 2 seconds, release the tamper key. If successful, the LED will light ON one second. Otherwise, the LED will flash once.
  3. IDs are excluded and all settings will reset to factory default.
Wakeup Information

To wake-up the device immediately, please remove the front cover, and press the tamper key once. The device will wake-up 10 seconds

Usage Information
Basic ClassBASIC_TYPE_ROUTING_SLAVE
Generic ClassGENERIC_TYPE_SENSOR_NOTIFICATION
Specific ClassSPECIFIC_TYPE_NOTIFICATION_SENSOR
Unique Referencemt02648

Configuration Parameters

Parameter 2
Bitmask
LabelBasic Set Level
DescriptionSetting the BASIC command value to turn on the light.
Word Size1
Default Value-1
Allowable Range-1 to 100
Overview

The 0xFF(-1) means turn on the light. For dimmer equipment 1 to 100 means the light strength. 0 means turn off the light.

Options
Parameter 3
Bitmask
LabelPIR Sensitivity
DescriptionPIR sensitivity settings.
Word Size1
Default Value70
Allowable Range0 to 99
Overview

0 means disable the PIR motion. 1 means the lowest sensitivity, 99 means the highest sensitivity. High sensitivity means can detected long distance, but if there is more noise signal in the environment, it will re-trigger too frequency. 

Options
Option Value0
Option LabelDisable PIR
Option Overview
Option Value1
Option LabelLowest sensitivity
Option Overview
Option Value99
Option LabelHighest sensitivity
Option Overview

High sensitivity means can detected long distance, but if there is more noise signal in the environment, it will re-trigger too frequency.

Parameter 4
Bitmask
LabelLight Threshold
DescriptionSetting the illumination threshold to turn on the light
Word Size1
Default Value100
Allowable Range0 to 100
Overview

When the event triggered and the environment illumination lower then the threshold, the device will turn on the light. 0 means turn off illumination detected function. And never turn on the light. 1 means darkest. 99 means brightest.100 means turn off illumination detected function. And always turn on the light.

Notice: In none test mode, only the value in 1 to 99 will enable the illumination detected function and update the illumination value. 

Options
Option Value0
Option LabelDisable (Light OFF)
Option Overview
Option Value100
Option LabelDisable (Light ON)
Option Overview
Parameter 5
Bitmask
LabelOperation Mode
DescriptionParameter to set the Operation Mode
Word Size1
Default Value0
Allowable Range0 to 127
Overview

Bit0: Reserve.

Bit1: 1 means enable test mode, 0 means disable normal mode. (Notice: This bit only effect by the DIP Switch setting to program mode.) 

Bit2: Disable the door/window function.

Bit3: Setting the temperature scale. 0: Fahrenheit, 1:Celsius

Bit4: Disable the illumination report after event triggered.

Bit5: Disable the temperature report after event triggered.

Bit6: Reserve.

Bit7: Disable the back key release into test mode.

Options
Option Value8
Option LabelCelsius and LED off = Bits: 00001000 = 8
Option Overview

Changes the Temperature Report to CELSIUS (Bit 3) and disables Test Mode (Bit 1) which causes the LED not to illuminate

Option Value10
Option LabelPreset: Celsius and LED on = Bits: 00001010 = 10
Option Overview

Changes the Temperature Report to CELSIUS (Bit 3) and enables Test Mode (Bit 1) which causes the LED to illuminate for 1 second when Door opens/closes

 

Parameter 6
Bitmask
LabelMulti-Sensor Function Switch
DescriptionParameter to set the sensor functions
Word Size1
Default Value4
Allowable Range0 to 127
Overview

Bit0: Disable magnetic integrate illumination.

Bit1: Disable PIR integrate Illumination.

Bit2: Disable magnetic integrate PIR (Default is Disable)

Bit3: When Bit2 is 0 (Enable), Are the device and the lighting in the same room? 0: In the same room(Default), 1: In the different room.

Notice: If this bit is 1, it is recommended also set the Bit1 to 1, cause the PIR triggered, doesn't mean the people in that room.

Bit4: Disable delay 5 seconds to turn off the light, when door/window closed.

Bit5: Disable auto turn off the light, after door/window opened to turn on the light.

Notice: If bit2 is zero, this setting is useless. Notice: If the configuration No.9 is zero, this setting is useless.

Bit6: Reserve.

Bit7: Reserve.

Options
Parameter 7
Bitmask
LabelCustomer Function
DescriptionParameter to set the Customer Function
Word Size1
Default Value4
Allowable Range0 to 127
Overview

Bit0: Reserve.

Bit1: Enable sending motion OFF report.

Note: Depends on the Bit4, 0: Report Notification CC, Type: 0x07, Event: 0xFE 1: Sensor Binary Report, Type: 0x0C, Value: 0x00

Bit2: Enable PIR super sensitivity mode.

Bit3: Enable don't send out BASIC OFF after door closed.

Bit4: Notification Type, 0: Using Notification Report. 1: Using Sensor Binary Report.

Bit5: Disable Multi CC in auto report.

Bit6: Disable to report battery state when the device triggered.

Bit7: Reserve.

Options
Option Value20
Option LabelPIR Super Sensitivity and Binary Report
Option Overview

Preset: PIR Super Sensitivity and Binary Report = Bits: 00010100 = 20

Enables the PIR Super Sensitivity (Bit 2) and changes the Notification Type to a Binary Report (Bit 4)

Parameter 8
Bitmask
LabelPIR Re-Detect Interval Time
DescriptionParameter to set the PIR Re-Detect Interval Time
Word Size1
Default Value3
Allowable Range1 to 127
Overview

In the normal mode, after the PIR motion detected, setting the re-detect time. 8 seconds per tick, default tick is 3 (24 seconds).

Setting the suitable value to prevent received the trigger signal too frequency. Also can save the battery energy.

Notice: If this value bigger than the configuration setting NO. 9. There is a period after the light turned off and the PIR not start detecting.

Options
Parameter 9
Bitmask
LabelTurn Off Light Time
DescriptionParameter to set the Turn Off Light Time
Word Size1
Default Value4
Allowable Range0 to 127
Overview

After turn on the lighting, setting the delay time to turn off the lighting when the PIR motion is not detected. 8 seconds per tick, default tick is 4 (32 seconds). 0 means never send turn off light command.

Options
Parameter 10
Bitmask
LabelAuto Report Battery Time
DescriptionParameter to set the Auto Report Battery Time
Word Size1
Default Value12
Allowable Range0 to 127
Overview

The interval time for auto report the battery level. 0 means turn off auto report battery. The default value is 12. The tick time can setting by the configuration No.20.

Options
Parameter 11
Bitmask
LabelAuto Report Door/Window State Time
DescriptionThe interval time for auto reporting the door/window state
Word Size1
Default Value12
Allowable Range0 to 127
Overview

The interval time for auto report the door/window state. 0 means turn off auto report door/window state. The default value is 12. The tick time can setting by the configuration No.20.

Options
Parameter 12
Bitmask
LabelAuto Report Illumination Time
DescriptionThe Interval time for auto reporting the illumination state
Word Size1
Default Value12
Allowable Range1 to 127
Overview

The interval time for auto report the illumination. 0 means turn off auto report illumination. The default value is 12. The tick time can setting by the configuration No.20.

Options
Parameter 13
Bitmask
LabelAuto Report Temperature Time
DescriptionThe interval time for auto reporting the temperature state
Word Size1
Default Value12
Allowable Range1 to 127
Overview

The interval time for auto report the temperature. 0 means turn off auto report temperature. The default value is 12. The tick time can setting by the configuration No.20.

Options
Parameter 20
Bitmask
LabelAuto Report Tick Interval
DescriptionThe interval time for each auto report tick
Word Size1
Default Value30
Allowable Range0 to 255
Overview

The interval time for auto report each tick. Setting this configuration will effect configuration No.10, No.11, No.12 and No.13. Caution: Setting to 0 means turn off all auto report function.

Options
Parameter 21
Bitmask
LabelTemperature Differential Report
DescriptionThe temperature differential to report
Word Size1
Default Value1
Allowable Range0 to 127
Overview

The temperature differential to report. 0 means turn off this function. The unit is Fahrenheit. Enable this function the device will detect every minutes. And when the temperature is over 140 degree Fahrenheit, it will continue report. Enable this functionality will cause some issue please see the detail in the “Temperature Report” section.

Options
Parameter 22
Bitmask
LabelIllumination Differential Report
DescriptionThe illumination differential to report
Word Size1
Default Value1
Allowable Range0 to 99
Overview

The illumination differential to report. 0 means turn off this function. The unit is percentage. Enable this function the device will detect every minutes. Enable this functionality will cause some issue please see the detail in the “Illumination Report” section.

Options

Association Groups

Group ID1
LabelReports
Description
Maximum Nodes8
ControllerYes
Overview
Group ID2
LabelLight Control
Description
Maximum Nodes8
ControllerNo
Overview

Endpoints

Endpoint NameEndpoint 0
Endpoint Number0
Basic ClassBASIC_TYPE_ROUTING_SLAVE
Generic ClassGENERIC_TYPE_SENSOR_NOTIFICATION
Specific ClassSPECIFIC_TYPE_NOTIFICATION_SENSOR
Command Classes
Class Ver Basic NIF Sec UnSec
NO_OPERATION 1
BASIC 1
SENSOR_BINARY 2
Door / Window Status
SENSOR_MULTILEVEL 5
Sensor (temperature)
Sensor (luminance)
ASSOCIATION_GROUP_INFO
DEVICE_RESET_LOCALLY 1
ZWAVE_PLUS_INFO 1
CONFIGURATION 1
ALARM 3
Alarm
MANUFACTURER_SPECIFIC 1
POWERLEVEL 1
FIRMWARE_UPDATE_MD
BATTERY 1
WAKE_UP 2
ASSOCIATION 1
VERSION 1
MULTI_CMD 1
SECURITY

Reference Documents

Product Image MT02648.jpeg
Device Manual Devolo-home-Control-Door-Window.pdf
Product Image devolo-home-control-tuer-fensterkontakt.jpg

First added to database on 2018-06-03 09:15:28. Current released version is 4.
Last updated by Super User on 2019-01-18 22:12:33 (3 months ago).
Approved on 2019-01-18 22:13:37, and last exported on 2019-01-18 22:13:39.

Add comment


Security code
Refresh