Device Overview

ManufacturerCooper Wiring Devices
Manufacturer ID001A
NameRF9540-N
Device DescriptionAll Load Dimmer Light Switch
CategoryWall Switch
References (Type:Id)4449:0101,4449:AA00
Firmware VersionsAll
Protocol Version3.067
Library TypeLIB_SLAVE_ENHANCED
Always ListeningYes
Frequently ListeningNo
Supports RoutingYes
Supports BeamingYes
Supports SecurityNo
Maximum Data Rate40000
Device Overview

OPERATION INSTRUCTIONS

  • Press once to turn lights ON at previously selected level.
  • Press again to turn lights OFF.
  • When lights are OFF, press and hold for 2 seconds for full brightness.
  • When lights are ON, press and hold for 2 seconds until the blue LED blinks. After the preset delay, the lights will begin fading to OFF (up to 4 minutes).
  • Amber ON/OFF LED indicates that dimmer is turned on.
Inclusion Information
  1. This product may be added to a new or existing Z-Wave network. A Cooper Wiring Devices Z-Wave device has a blue LED, which will blink when the device is not included in a Z-Wave network. The LED stops blinking when the device is in a network.
  2. To include this device in a Z-Wave network, select the command on your Z Wave controller for inclusion (Install, Add Device, Add Node, Include Device, etc.). Then press the device switch one time to include it in the network. The LED will stop blinking.
Exclusion Information

To exclude this device from a Z-Wave network, select the command on your Z-Wave controller for exclusion (Uninstall, Remove Device, Remove Node, Exclude Device, etc.). Then press the device switch one time to exclude it from the network. The LED will start blinking.

Usage Information
Basic ClassBASIC_TYPE_ROUTING_SLAVE
Generic ClassGENERIC_TYPE_SWITCH_MULTILEVEL
Specific ClassSPECIFIC_TYPE_SCENE_SWITCH_MULTILEVEL
Unique Referencerf9540n

Configuration Parameters

Parameter 1
Bitmask
LabelDelayed OFF time
Descriptiontime in seconds to delay OFF
Word Size1
Default Value0
Allowable Range0 to 255
Overview

The amount of time in seconds the switch will delay when trigger the delayed off feature

Options
Parameter 2
Bitmask
LabelPanic ON time
DescriptionTime in seconds for panic mode ON
Word Size1
Default Value0
Allowable Range0 to 255
Overview

The amount of time in seconds the switch will turn on for when panic mode is triggered

Options
Parameter 3
Bitmask
LabelPanic OFF time
Descriptiontime in seconds for OFF in panic mode
Word Size1
Default Value0
Allowable Range0 to 255
Overview

The amount of time in seconds the switch will turn off for when panic mode is triggered

Options
Parameter 4
Bitmask
LabelBasic Set Value
DescriptionSend value to association group on trigger
Word Size1
Default Value0
Allowable Range0 to 255
Overview

Setting this to anything other than 0 will cause the value to be transmitted to devices in the association group when the switch is triggered. A setting other than 0 will likely result in undesired operation

Options
Parameter 5
Bitmask
LabelPower Up State
DescriptionPower Up State of the switch
Word Size1
Default Value1
Allowable Range0 to 255
Overview
Options
Option Value1
Option LabelOFF
Option Overview
Option Value2
Option LabelON
Option Overview
Option Value3
Option LabelLast State
Option Overview
Parameter 6
Bitmask
LabelPanic mode enable
DescriptionEnables this switch to participate in panic mode
Word Size1
Default Value1
Allowable Range0 to 255
Overview
Options
Option Value1
Option LabelOFF
Option Overview
Option Value2
Option LabelON
Option Overview
Parameter 7
Bitmask
LabelDimmer Ramp Time
DescriptionTime in seconds to reach desired level
Word Size1
Default Value0
Allowable Range0 to 255
Overview

The amount of time in seconds the switch will take to reach the desired dim level

Options
Parameter 8
Bitmask
LabelKickstart / Rapid Start
DescriptionTurn on or off rapid start feature
Word Size1
Default Value1
Allowable Range0 to 255
Overview

Ensures that LED / CFL bulbs turn on when the preset dim level is low.  Enabling this feature may cause the lights brightness to momentarily be bright when the switch is turned on before reducing in brightness to desired level

Options
Option Value1
Option LabelOFF
Option Overview
Option Value2
Option LabelON
Option Overview
Parameter 11
Bitmask
LabelMinimum Dimmer Level
DescriptionThe minimum dim level the switch will allow
Word Size1
Default Value4
Allowable Range4 to 99
Overview
Options
Parameter 12
Bitmask
LabelMaximum Dimmer Level
DescriptionThe maximum dim level the switch will allow
Word Size1
Default Value99
Allowable Range4 to 99
Overview
Options

Association Groups

Group ID1
LabelGroup 1
Description
Maximum Nodes5
ControllerYes
Overview
Group ID255
LabelGroup 255
Description
Maximum Nodes1
ControllerYes
Overview

Life line to the controller

Endpoints

Endpoint NameEndpoint 0
Endpoint Number0
Basic ClassBASIC_TYPE_ROUTING_SLAVE
Generic ClassGENERIC_TYPE_SWITCH_MULTILEVEL
Specific ClassSPECIFIC_TYPE_SCENE_SWITCH_MULTILEVEL
Command Classes
Class Ver Basic NIF Sec UnSec
NO_OPERATION 1
BASIC 1
SWITCH_MULTILEVEL 2
Dimmer
SWITCH_ALL 1
SCENE_ACTIVATION 1
Scene Number
SCENE_ACTUATOR_CONF
CONFIGURATION 1
Dimmer Ramp Time
ALARM 1
Alarm
MANUFACTURER_SPECIFIC 1
POWERLEVEL 1
PROTECTION 1
Local Device Protection
NODE_NAMING 1
HAIL 1
ASSOCIATION 1
VERSION 1
INDICATOR 1
Indicator Light Control

Reference Documents

Product Image RF9540-NDW-l-220.jpg
User Manual Users-Manual-3690445.pdf

First added to database on 2018-01-20 09:01:46. Current released version is 4.
Last updated by sihui on 2018-07-22 07:03:27 (11 months ago).
Approved on 2018-07-22 07:07:45, and last exported on 2018-12-09 10:39:58.

Comments  

# Jay Matz 2018-01-08 11:08
I'd like to add a "protection_local" channel under the PROTECTION command class. I do not see a way to do this. I also created an erroneous duplicate of protection.
Reply | Reply with quote | Quote

Add comment


Security code
Refresh