Please note that editing on this site is now closed. We have moved to a new site right across the road at OpenSmartHouse. The new site offers a better user experience and existing users already registered here with permission to edit the database have been migrated and should be able to log on using the request password link.
Goto this device in the new site
  • Endpoint 0 has no command class linked to the basic class.

Device Overview

ManufacturerEcolink
Manufacturer ID014A
NameDWZWAVE2
Device DescriptionZ-Wave Door/Window Sensor
CategoryDoor
References (Type:Id)0001:0002
Firmware VersionsAll
Protocol Version3.040
Library TypeLIB_CONTROLLER_BRIDGE
Always ListeningNo
Frequently ListeningNo
Supports RoutingYes
Supports BeamingNo
Supports SecurityNo
Maximum Data Rate
Device Overview
  • Z-Wave enabled device which provides open/closed status
  • Transmits open/closed status
  • Reports tamper condition when cover is open
Inclusion Information
  1. Remove the battery for at least 5 seconds,
  2. Reinstall the battery
  3. Replace the sensor cover
Exclusion Information
  1. Remove the battery from the Sensor.
  2. Leave the battery out for at least ten (10) seconds.
  3. Reinstall the battery into the Sensor.
Wakeup Information

Press the "+" button once.

Usage Information
Basic ClassBASIC_TYPE_ROUTING_SLAVE
Generic ClassGENERIC_TYPE_SENSOR_BINARY
Specific ClassSPECIFIC_TYPE_ROUTING_SENSOR_BINARY
Unique Referencedwzwave2

Configuration Parameters

Parameter 1
Bitmask
LabelSending Basic Sets to Association group 2
DescriptionSending Basic Sets to Association group 2
Word Size1
Default Value0
Allowable Range0 to 255
Overview
Options
Option Value0
Option LabelOff
Option Overview
Option Value255
Option LabelOn
Option Overview
Parameter 2
Bitmask
LabelSending sensor binary report
DescriptionSending sensor binary report
Word Size1
Default Value0
Allowable Range0 to 255
Overview
Options
Option Value0
Option LabelOff
Option Overview
Option Value255
Option LabelOn
Option Overview

Association Groups

Group ID1
LabelGroup 1
DescriptionAssociation Group 1
Maximum Nodes5
ControllerYes
Overview

Association group one is intended for but not limited to controllers. All nodes whose Node ID that have been set in Association group one will receive all unsolicited Alarm Report frames, and Basic Report frames of 0x00 and 0xFF.  When a sensor such as a door or window sensor is opened/faulted, the sensor will send a Basic Report to nodes in Association group one and a Basic Set of 0xFF to Association group two. When the door or window is closed the sensor will send a Basic Report of 0x00 to only group one.

Group ID2
LabelGroup 2
DescriptionAssociation Group 2
Maximum Nodes5
ControllerNo
Overview

Association group two is intended for any device Ecolink Z-Wave Command Class Specification 2 that is controllable with a Basic Set of 0xFF such as lights, sirens, or chimes. When a sensor such as a door or window sensor is opened/faulted, the sensor will send a Basic Report to nodes in Association group one and a Basic Set of 0xFF to Association group two. When the door or window is closed the sensor will send a Basic Report of 0x00 to only group one. The Configuration command class can configure the sensor to send Basic Sets of 0x00 to nodes in group two (turning devices off).

Endpoints

Endpoint NameEndpoint 0
Endpoint Number0
Basic ClassBASIC_TYPE_ROUTING_SLAVE
Generic ClassGENERIC_TYPE_SENSOR_BINARY
Specific ClassSPECIFIC_TYPE_ROUTING_SENSOR_BINARY
Command Classes
Class Ver Basic NIF Sec UnSec
NO_OPERATION 1
BASIC 1
SENSOR_BINARY 1
Binary Sensor
CONFIGURATION 1
ALARM 2
Alarm
MANUFACTURER_SPECIFIC 2
BATTERY 1
WAKE_UP 2
ASSOCIATION 2
VERSION 2

Reference Documents

User Manual Ecolink-DWZWAVE2-ECO-manual-rev1.pdf
Technical Manual Advanced-Zwave-Configuration-v2.pdf
Product Image Ecolink-DWZWAVE2-ECO.jpg

First added to database on 2017-02-25 22:52:25. Current released version is 4.
Last updated by Bruce Osborne on 2019-09-01 15:18:34 (1 year ago).
Approved on 2019-09-01 20:12:29, and last exported on 2019-12-25 13:23:22.

Comments  
# Geoff Sulcer 2017-02-12 15:16
If I understand what I've read, to use this properly with OH2, the command class SENSOR_BINARY should change to SENSOR_DOOR, is that correct?
# Super User 2017-02-12 15:21
No - there is no such command class as SENSOR_DOOR. The channel type is already set to sensor_door. I'd suggest to discuss whatever problem you might be experiencing on the openhab forum.
# Ryan W 2017-02-24 20:22
Just purchased this, it is coming up with a different Device Type / Device ID: 014A:0004:0002:10.1

I tried updating the XML with no success.

I am using Openhab2 2.0.0-1 (Stable)
# Ryan W 2017-02-24 20:52
I was able to get the device added, by editing the JAR file in:
/var/lib/openhab2/tmp/mvn/org/openhab/binding/org.openhab.binding.zwave/2.0.0/org.openhab.binding.zwave-2.0.0.jar

Edited the file:
/home/copie/ESH-INF/thing/eco_dwzwave2_0_0.xml

Uninstalled / Re-installed the binding and it worked. However, if the Type and Device ID's are added it would be nice for next update :)
# Super User 2017-02-24 20:59
I've added the updates, but please remember that you can always edit the database yourself ;)
# Brady 2017-06-29 04:04
(removed a comment as it may have contained some misleading information)
# Mark Hilbush 2018-11-24 20:09
I'm going to move device type;id 0004:0002 to its own database entry (DWZWAVE25) as this is a Z-Wave Plus device that has additional command classes and config parameters that the DWZWAVE2 device doesn't support.

You have no rights to post comments