• Endpoint 0 has no command class linked to the basic class.

Device Overview

ManufacturerLinear Corp
Manufacturer ID014F
NameNGD00Z-4
Device DescriptionGarage Door Controller
CategoryGarage Door
References (Type:Id)4744:3030,4744:3032,4744:3530
Firmware VersionsAll
Protocol Version4.005
Library TypeLIB_SLAVE_ENHANCED
Always ListeningYes
Frequently ListeningNo
Supports RoutingYes
Supports BeamingYes
Supports SecurityNo
Maximum Data Rate40000
Device Overview

GARAGE DOOR OPENER REMOTE COMMAND TRANSCEIVER with TILT SENSOR

Inclusion Information

TO INCLUDE THE GD00Z-4 INTO YOUR CONTROLLER

  1. Place your Z-Wave Controller into Discovery or Include mode.
  2. Press and release the link button on the GD00Z-4.
  3. Confirm that the GD00Z-4 was recognized by your Z-Wave Controller.
Exclusion Information

TO EXCLUDE THE GD00Z-4 FROM YOUR CONTROLLER

  1. Place your Z-Wave Controller into Exclude mode.
  2. Press and release the link button on the GD00Z-4.
  3. Confirm that the GD00Z-4 was excluded by your Z-Wave Controller.
Usage Information
Basic ClassBASIC_TYPE_ROUTING_SLAVE
Generic ClassGENERIC_TYPE_ENTRY_CONTROL
Specific ClassSPECIFIC_TYPE_SECURE_BARRIER_ADDON
Unique Referencengd00z4

Configuration Parameters

None

Association Groups

Group ID1
LabelGroup 1
Description
Maximum Nodes1
ControllerYes
Overview

Endpoints

Endpoint NameEndpoint 0
Endpoint Number0
Basic ClassBASIC_TYPE_ROUTING_SLAVE
Generic ClassGENERIC_TYPE_ENTRY_CONTROL
Specific ClassSPECIFIC_TYPE_SECURE_BARRIER_ADDON
Command Classes
Class Ver Basic NIF Sec UnSec
NO_OPERATION 1
BASIC 1
APPLICATION_STATUS
DEVICE_RESET_LOCALLY 1
BARRIER_OPERATOR 1
Barrier State
ALARM 3
Alarm (raw)
MANUFACTURER_SPECIFIC 1
ASSOCIATION 1
VERSION 1
SECURITY 1

Reference Documents

Install manual linear-GD00Z4-Install--company-now-known-as-nortek-security.pdf
Product Image NGD00Z.jpg

First added to database on 2018-05-17 20:59:35. Current released version is 3.
Last updated by Lenny Shirley II on 2018-05-14 00:27:51 (11 months ago).
Approved on 2018-05-17 20:09:14, and last exported on 2018-12-09 10:39:53.

Comments  

# Ash Gupta 2017-04-10 19:55
Alarm Channels need to be updated. There are 2 Alarm Channels.
Alarm Type = BURGLAR --> This is activated if the Door Sensor is opened/tampered.
Alarm Type = ACCESS_CONTROL --> This is activated if Sensor Battery is Low, or Obstruction observed at Garage Door preventing it from Closing. The values are:
Alarm Type: BURGLAR, Event Value: 3 = Case Open/Tamper
Alarm Type: BURGLAR, Event Value: 0 = Tamper Closed / Case Closed

Alarm Type: ACCESS_CONTROL (0), Event Value: 74 = Low Battery
Alarm Type: ACCESS_CONTROL (0), Event Value: 70 = Garage Door is obstructed
Alarm Type: ACCESS_CONTROL (0), Event Value: 69 = Garage Door is obstructed twice, operation suspended
Alarm Type: ACCESS_CONTROL (0), Event Value: 0 = Obstruction Cleared/Alarm Cleared
Reply | Reply with quote | Quote
# Ash Gupta 2017-04-12 18:45
Replaced barrier_position channel with barrier_state
barrier_state seems is the exact channel that provides for all of the states of the door.

Added channels for:
BURGLAR_ALARM: notification_home_security
ACCESS_CONTROL_ALARM: notification_access_control
Reply | Reply with quote | Quote
# Ash Gupta 2017-04-13 01:15
Chris - I have updated the database with 16 channels. 14 have proper names and event ids.

2 Channels are generic channels for Events that I don't think are relevant but might be relevant. I have not been able to perform all testing to make sure that the other zWave type events are not applicable.
eg: Manual Lock/Unlock, Keypad Lock/Unlock might be relevant for the Garage Door but I have not tested them yet.
Reply | Reply with quote | Quote
# Howard Cardwell 2017-04-15 21:06
Quoting Ash Gupta:
Chris - I have updated the database with 16 channels. 14 have proper names and event ids.

2 Channels are generic channels for Events that I don't think are relevant but might be relevant. I have not been able to perform all testing to make sure that the other zWave type events are not applicable.
eg: Manual Lock/Unlock, Keypad Lock/Unlock might be relevant for the Garage Door but I have not tested them yet.


Hi Ash. I cannot seem to get usable items using this setup for the controller. What do you bind the items to for control and viewing of door position?
Reply | Reply with quote | Quote
# Alex Sok 2017-04-23 05:53
Ash,

Are you able to control the door with this configuration? Or is it only allows you to view current state?

Thank you,
Alex
Reply | Reply with quote | Quote
# Lenny Shirley II 2018-05-13 23:29
Quoting Alex Sok:
Ash,

Are you able to control the door with this configuration? Or is it only allows you to view current state?

Thank you,
Alex


I just purchased this device, and cannot seem to find a way to operate the device using OpenHab. Anybody have any luck?
Reply | Reply with quote | Quote
# Ash Gupta 2017-04-17 21:18
Alerts Labels made user friendly.
Reply | Reply with quote | Quote
# Ash Gupta 2017-04-25 21:55
Changed:
AccessControl Alert (UnMatched Code) TO number type: notification_access_control
Burglar Alert (UnMatched Code) TO number type: notification_home_security

This is to report the exact alert so that we can use it in rules to manually update a virtual switch based on the value.
Reply | Reply with quote | Quote

Add comment


Security code