• Endpoint 0 contains both switch and dimmer channels. It probably should only include dimmer!
  • Endpoint 0 has no command class linked to the basic class.

Device Overview

ManufacturerMOBILUS MOTOR Spólka z o.o.
Manufacturer ID019D
NameEZRS
Device DescriptionMobilus Tubular Motor
CategoryBlinds
References (Type:Id)0002:0001,0003:0010
Firmware VersionsAll
Protocol Version6.002
Library TypeLIB_SLAVE_ENHANCED
Always ListeningYes
Frequently ListeningNo
Supports RoutingYes
Supports BeamingYes
Supports SecurityNo
Maximum Data Rate40000
Device Overview

Tubular motor mob.iq EZRS M35 10/14 by Mobilus Motor Company is a modern radio controllable drive, designed to drive rolling shields. This device has a number of innovative solutions, including:

SENSO technology

  • programming of endpoints automatically or using the remote control, 
  • operation regardless of the used hangers type, 
  • bidirectional obstacles detection which eliminates failures due to obstacles (each failure will be reported to controller as an alarm)
  • saving your time due to lack of supervision of your shutters - obstacle detection system, insensitive to minor disruption during work.

Communication standard

But the most important feature of our motor is the usage of Z-Wave technology as the communication standard. It provides inter alia

  • easy procedure of connection the device to the network,
  • bidirectional communication between the motor operator and control device - therefore the user has the opportunity to receive a variety of information about the motor operator (location, work errors, obstacles encountered in the blinds way of work), 
  • automatic creation of network of devices, so there is no need for additional radio signal repeaters, 
  • compatibility with third party control devices - Z-Wave is a mature standard for radio communication, chosen by over two hundred manufacturers of devices intended to create an intelligent home control systems.

Technical parameters

  • fi roller tube diameter of 35 mm,
  • torque: 10 Nm, 
  • revolutions per minute: 14 rpm, 
  • supply voltage 230 V.
Inclusion Information
  1. Plug mob.iq [ M35 EZRS ] motor to the power supply according to schema at the end of instruction. Green diode in PROGRAMMING BUTTON is on. In the other case you need to exclude motor from Z-Wave network according to point 4 of this instruction.
  2. Turn your controller into INCLUDE mode (see instruction of your controller).
  3. Press the PROGRAMMING BUTTON on mob.iq [ M35 EZRS ] motor.
  4. Motor is detected by controller and included into Z-Wave network - the led diode is off.
Exclusion Information
  1. Turn your controller into exclude mode (see instruction of your controller).
  2. Press the PROGRAMMING BUTTON on mob.iq [ M35 EZRS ] motor.
  3. Motor is detected by controller and excluded from Z-Wave network - the led diode is on.
Usage Information
Basic ClassBASIC_TYPE_ROUTING_SLAVE
Generic ClassGENERIC_TYPE_SWITCH_MULTILEVEL
Specific ClassSPECIFIC_TYPE_CLASS_C_MOTOR_CONTROL
Unique Referencem35ezrs

Configuration Parameters

Parameter 12
Bitmask
LabelMotor state mode
DescriptionAllows to change motor state (normal/calibration/discalibration mode)
Word Size1
Default Value0
Allowable Range0 to 0
Overview
Options
Option Value0
Option LabelNormal mode (default)
Option Overview
Option Value1
Option LabelCalibration mode
Option Overview
Option Value2
Option LabelDiscalibration mode
Option Overview

Reset of the tubular motor - restore presets.

Parameter 13
Bitmask
LabelBASIC SET Respone
DescriptionAllows to change motor behavior after receiving BASIC_SET with value 0xFF
Word Size1
Default Value0
Allowable Range0 to 0
Overview
Options
Option Value0
Option Labellast known non-zero position (default)
Option Overview
Option Value1
Option Labelmax open
Option Overview

Association Groups

Group ID1
LabelI ASSOCIATION GROUP
DescriptionAllows to send information about failures, errors and alarms directly to the controller (max. 5 devices).
Maximum Nodes5
ControllerYes
Overview
Group ID2
LabelII ASSOCIATION GROUP
DescriptionAllows to send direct steering commands between SLAVE devices without participation of PRIMARY controller (max. 5 devices).
Maximum Nodes5
ControllerNo
Overview
Group ID3
LabelIII ASSOCIATION GROUP
DescriptionAllows to send direct steering commands (BASIC_SET with value 0xFF) to other devices if error is detected (max. 5 devices).
Maximum Nodes5
ControllerNo
Overview

Endpoints

Endpoint NameEndpoint 0
Endpoint Number0
Basic ClassBASIC_TYPE_ROUTING_SLAVE
Generic ClassGENERIC_TYPE_SWITCH_MULTILEVEL
Specific ClassSPECIFIC_TYPE_CLASS_C_MOTOR_CONTROL
Command Classes
Class Ver Basic NIF Sec UnSec
NO_OPERATION 1
BASIC 1
SWITCH_BINARY 1
Switch
SWITCH_MULTILEVEL 3
Dimmer [deprecated]
Blinds Control
ASSOCIATION_GROUP_INFO 1
DEVICE_RESET_LOCALLY 1
ZWAVE_PLUS_INFO 1
CONFIGURATION 1
ALARM 8
Alarm (system)
MANUFACTURER_SPECIFIC 1
POWERLEVEL 1
NODE_NAMING 1
ASSOCIATION 2
VERSION 2
SECURITY 1

Reference Documents

Manual mob-iq-ezrs-eng.pdf
Product Image ezrs.jpg

First added to database on -0001-11-30 00:00:00. Current released version is 3.
Last updated by Super User on 2019-08-10 23:00:54 (3 months ago).
Approved on 2019-08-10 23:01:29, and last exported on 2019-09-16 22:05:02.

Comments  
# Michal Chudy 2019-03-14 21:43
I've just tested it on 2.5.0-SNAPSHOT and it works well. It even allows to set shutter at any % you want. The only thing that bugs me is that both configuration options, which are exposed are pretty risky and should be never used at normal operation.
Reply | Reply with quote | Quote
Add comment