Device Overview

ManufacturerDevolo
Manufacturer ID0175
NameMT02646
Device DescriptionHome Control Metering Plug
CategoryPower Outlet
References (Type:Id)0001:0011
Firmware VersionsAll
Protocol Version3.083
Library TypeLIB_SLAVE_ENHANCED
Always ListeningYes
Frequently ListeningNo
Supports RoutingYes
Supports BeamingYes
Supports SecurityNo
Maximum Data Rate40000
Device Overview

The Home Control Smart Metering Plug can be plugged into any wall outlet in the home. It enhances every
connected device with useful functions, such as time-controlled enabling and disabling or power monitoring

Inclusion Information

Push the front button three times rapidly within 2 seconds.

Exclusion Information

Push the front button three times rapidly within 2 seconds.

Usage Information
Basic ClassBASIC_TYPE_ROUTING_SLAVE
Generic ClassGENERIC_TYPE_SWITCH_BINARY
Specific ClassSPECIFIC_TYPE_POWER_SWITCH_BINARY
Unique Referencemt02646

Configuration Parameters

Parameter 1
Bitmask
LabelWatt Meter Report Period
Descriptionmultiples of 5s
Word Size2
Default Value720
Allowable Range0 to 32767
Overview

Enable automatic interval in seconds reporting with an interval of 5s * the value. Set to 0 will disable the autoreporting function.

Options
Option Value0
Option LabelDisable
Option Overview
Parameter 2
Bitmask
LabelKWH Meter Report Period
Descriptionnumber of 10 minute intervals
Word Size2
Default Value6
Allowable Range0 to 32767
Overview

Enable automatic interval in minutes reporting with an interval of 10min * the value. Set to 0 will disable the autoreporting function.

Options
Option Value0
Option LabelDisable
Option Overview
Parameter 3
Bitmask
LabelThreshold of current for Load Caution
Description1300*0.01A = 13A
Word Size2
Default Value1300
Allowable Range10 to 1300
Overview
Options
Parameter 4
Bitmask
LabelThreshold of KWh for Load Caution
Descriptionload caution threshold
Word Size2
Default Value10000
Allowable Range1 to 10000
Overview

Enable automatic warning when the accumulated kWh power consumption exceeds the setting value from 1KWh ~ 10000KWh.. Set to 0 will disable kWh load caution reporting.

Options
Parameter 5
Bitmask
LabelRestore switch state mode
DescriptionRestore switch state mode.
Word Size1
Default Value1
Allowable Range0 to 255
Overview
Options
Option Value0
Option LabelSwitch OFF after power on
Option Overview

Upon the return of AC power, the switch will remain Off.

Option Value1
Option Labelresume previous state
Option Overview

Upon the return of AC power, the switch will return to the state it was

Option Value2
Option LabelSwitch ON after power on
Option Overview

Upon the return of AC power, the switch will turn On.

Parameter 6
Bitmask
LabelMode of switch off function
DescriptionMode of switch off function.
Word Size1
Default Value1
Allowable Range0 to 255
Overview
Options
Option Value0
Option LabelSWITCH OFF commands received are ignored.
Option Overview
Option Value1
Option LabelSWITCH OFF commands received are honored.
Option Overview
Parameter 7
Bitmask
LabelLED indication mode
DescriptionRestore switch state mode.
Word Size1
Default Value1
Allowable Range0 to 255
Overview
Options
Option Value1
Option LabelThe LED follows the state of the switch.
Option Overview
Option Value2
Option LabelLED off with load ON
Option Overview

Night Mode - When the switch is On, the LED is Off, and when the switch is off LED is on

Option Value3
Option LabelFlash mode
Option Overview

Flash Mode - When the state of the switch changes, the LED will be on

Parameter 8
Bitmask
LabelAuto off timer
DescriptionAuto off timer. 0 will disable the auto off function.
Word Size2
Default Value0
Allowable Range0 to 255
Overview
Options
Option Value0
Option LabelDisable
Option Overview
Parameter 9
Bitmask
LabelRF off command mode
DescriptionRF off command mode
Word Size1
Default Value0
Allowable Range0 to 255
Overview
Options
Option Value0
Option LabelSWITCH ALL OFF turns Switch OFF
Option Overview

When SWITCH ALL OFF is received, the MT02646 turns Off.

Option Value1
Option LabelIgnore ALL OFF
Option Overview
Option Value2
Option LabelIf ALL OFF is received, turn ON if it is OFF
Option Overview

When SWITCH ALL OFF is received, the MT02646 will turn On if it is Off

Option Value3
Option LabelSWITCH ALL OFF turns Switch ON
Option Overview

When SWITCH ALL OFF is received, the MT02646 turns On.

Association Groups

Group ID1
LabelReports
DescriptionGrouping 1 includes, SWITCH_BINARY_REPORT, METER_REPORT, ALARM_REPORT.
Maximum Nodes1
ControllerYes
Overview

Endpoints

Endpoint NameEndpoint 0
Endpoint Number0
Basic ClassBASIC_TYPE_ROUTING_SLAVE
Generic ClassGENERIC_TYPE_SWITCH_BINARY
Specific ClassSPECIFIC_TYPE_POWER_SWITCH_BINARY
Command Classes
Class Ver Basic NIF Sec UnSec
NO_OPERATION 1
BASIC 1
SWITCH_BINARY 1
Switch
SWITCH_ALL 1
METER 3
Electric meter (watts)
Electric meter (power factor)
Electric meter (kWh)
Electric meter (amps)
Electric meter (volts)
Reset the total power consumption
ASSOCIATION_GROUP_INFO 1
DEVICE_RESET_LOCALLY 1
ZWAVE_PLUS_INFO 2
CONFIGURATION 1
ALARM 1
Alarm
MANUFACTURER_SPECIFIC 2
POWERLEVEL 1
PROTECTION 2
FIRMWARE_UPDATE_MD 2
ASSOCIATION 2
VERSION 2
SECURITY 1

Reference Documents

English User Manual Manual-devolo-Home-Control-Metering-Plug-com.pdf
Product Image MT02646.jpeg

First added to database on 2018-01-08 23:31:50. Current released version is 11.
Last updated by sihui on 2018-07-22 05:41:40 (9 months ago).
Approved on 2018-07-22 05:42:08, and last exported on 2018-12-09 10:39:45.

Comments  

# Kake Monsteret 2017-10-26 17:33
Something went wrong when uploading an XML. Please remove this device.
Reply | Reply with quote | Quote
# Guest 2018-10-30 16:42
This comment has been deleted by Administrator

Add comment


Security code