The following table lists the channels that can be defined in the openHAB-2 Z-Wave binding. Channels are used within the binding to expose a devices functionality, and provides the default names for items, as well as the options that will be displayed in the user interface.

 

Channel Label

Channel Name

Item Type

Options

Burglar alarm

alarm_burglar

Switch

ON = Ok

OFF= Alarm

Carbon-monoxide alarm

alarm_co

Switch

ON = Ok

OFF = Alarm

Carbon-dioxide alarm

alarm_co2

Switch

ON = Ok

OFF = Alarm

Entry alarm

alarm_entry

Switch

ON = Open

OFF = Closed

Flood alarm

alarm_flood

Switch

ON = Ok

OFF= Closed

General alarm

alarm_general

Switch

ON = Ok

OFF = Alarm

Heat alarm

alarm_heat

Switch

ON = Ok

OFF = Alarm

Motion alarm

alarm_motion

Switch

ON = Ok

OFF = Alarm

Smoke alarm

alarm_smoke

Switch

ON = Ok

OFF = Alarm

Color

color_color

Color

 

Color temperature

color_temperature

Dimmer

 

Electric Current Consumption

meter_current

Number

 

Energy Consumption

meter_kvah

Number

 

Energy Consumption

meter_kwh

Number

 

Power factor

meter_powerfactor

Number

 

Meter Reset

meter_reset

Switch

 

Voltage

meter_voltage

Number

 

Electric Power Consumption

meter_watts

Number

 

Scene Number

scene_number

 Number  

Binary Sensor

sensor_binary

Switch

ON = Triggered

OFF = Untriggered

Door Sensor

sensor_door

Contact

OPEN = Open

CLOSED = Closed

Luminance

sensor_luminance

Number

 

Energy consumption

sensor_power

Number

 

Humidity

sensor_relhumidity

Number

 

Temperature

sensor_temperature

Number

 

Switch

switch_binary

Switch

 

Brightness

switch_dimmer

Dimmer

 

Heating Setpoint

thermostat_setpoint

Number

 

Fan Mode

thermostat_fan_mode

Number

0=Auto

1=On

2=Auto High

3=On High

6=Circulate

Fan Mode

thermostat_fan_state

Number

0=Idle

1=Running

2=Running High

Fan Mode

thermostat_state

Number

0=Idle

1=Heating

2=Cooling

3=Fan Only

4=Pending Heat

5=Pending Cool

6=Vent / Economiser

Thermostat Mode

thermostat_mode

Number

0=Off

1=Heat

2=Cool

3=Auto

4=Aux Heat

5=Resume

6=Fan Only

7=Furnace

8=Dry Air

9=Moist Air

10=Auto Changeover

11=Heat Economy

12=Cool Economy

13=Away

 

 

 

Add comment